TUD

Institut für Automatisierungstechnik

On-Line Measuring Method for the Concentration of Peroxodisulphate

Giebler, E.:

Transactions of the Institute of Metal Finishing 82 (2004) 3/4, 75-82

A steady state model of counter-current rinsing systems is introduced. The model is formulated in a compact matrix form which, in contrast to conventional descriptions, can be applied to a wide range of special cases by use of adequate matrices and vectors. The necessary formation rules are presented for a simple cascade rinsing system and for rinsing systems with pre rinsing, imperfect mixing and spray rinsing. An example demonstrates the use of the matrix model for the calculation of different variants of a cascade rinsing systems. Advantages and limits of the matrix model are discussed.

Stand: 01.09.2006 16:08
Autor: Webmaster IFA